Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 154
Filtrar
1.
Explor Target Antitumor Ther ; 5(1): 74-84, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38464383

RESUMO

Aim: To investigate magnetic resonance imaging (MRI)-based peritumoral texture features as prognostic indicators of survival in patients with colorectal liver metastasis (CRLM). Methods: From 2007-2015, forty-eight patients who underwent MRI within 3 months prior to initiating treatment for CRLM were identified. Clinicobiological prognostic variables were obtained from electronic medical records. Ninety-four metastatic hepatic lesions were identified on T1-weighted post-contrast images and volumetrically segmented. A total of 112 radiomic features (shape, first-order, texture) were derived from a 10 mm region surrounding each segmented tumor. A random forest model was applied, and performance was tested by receiver operating characteristic (ROC). Kaplan-Meier analysis was utilized to generate the survival curves. Results: Forty-eight patients (male:female = 23:25, age 55.3 years ± 18 years) were included in the study. The median lesion size was 25.73 mm (range 8.5-103.8 mm). Microsatellite instability was low in 40.4% (38/94) of tumors, with Ki-ras2 Kirsten rat sarcoma viral oncogene homolog (KRAS) mutation detected in 68 out of 94 (72%) tumors. The mean survival was 35 months ± 21 months, and local disease progression was observed in 35.5% of patients. Univariate regression analysis identified 42 texture features [8 first order, 5 gray level dependence matrix (GLDM), 5 gray level run time length matrix (GLRLM), 5 gray level size zone matrix (GLSZM), 2 neighboring gray tone difference matrix (NGTDM), and 17 gray level co-occurrence matrix (GLCM)] independently associated with metastatic disease progression (P < 0.03). The random forest model achieved an area under the curve (AUC) of 0.88. Conclusions: MRI-based peritumoral heterogeneity features may serve as predictive biomarkers for metastatic disease progression and patient survival in CRLM.

2.
Radiology ; 310(3): e232298, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38441091

RESUMO

Gastrointestinal (GI) bleeding is the most common GI diagnosis leading to hospitalization within the United States. Prompt diagnosis and treatment of GI bleeding is critical to improving patient outcomes and reducing high health care utilization and costs. Radiologic techniques including CT angiography, catheter angiography, CT enterography, MR enterography, nuclear medicine red blood cell scan, and technetium-99m pertechnetate scintigraphy (Meckel scan) are frequently used to evaluate patients with GI bleeding and are complementary to GI endoscopy. However, multiple management guidelines exist, which differ in the recommended utilization of these radiologic examinations. This variability can lead to confusion as to how these tests should be used in the evaluation of GI bleeding. In this document, a panel of experts from the American College of Gastroenterology and Society of Abdominal Radiology provide a review of the radiologic examinations used to evaluate for GI bleeding including nomenclature, technique, performance, advantages, and limitations. A comparison of advantages and limitations relative to endoscopic examinations is also included. Finally, consensus statements and recommendations on technical parameters and utilization of radiologic techniques for GI bleeding are provided. © Radiological Society of North America and the American College of Gastroenterology, 2024. Supplemental material is available for this article. This article is being published concurrently in American Journal of Gastroenterology and Radiology. The articles are identical except for minor stylistic and spelling differences in keeping with each journal's style. Citations from either journal can be used when citing this article. See also the editorial by Lockhart in this issue.


Assuntos
Hemorragia Gastrointestinal , Radiologia , Humanos , Hemorragia Gastrointestinal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Angiografia , Cateteres
3.
Acad Radiol ; 31(2): 417-425, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38401987

RESUMO

RATIONALE AND OBJECTIVES: Innovation is a crucial skill for physicians and researchers, yet traditional medical education does not provide instruction or experience to cultivate an innovative mindset. This study evaluates the effectiveness of a novel course implemented in an academic radiology department training program over a 5-year period designed to educate future radiologists on the fundamentals of medical innovation. MATERIALS AND METHODS: A pre- and post-course survey and examination were administered to residents who participated in the innovation course (MESH Core) from 2018 to 2022. Respondents were first evaluated on their subjective comfort level, understanding, and beliefs on innovation-related topics using a 5-point Likert-scale survey. Respondents were also administered a 21-question multiple-choice exam to test their objective knowledge of innovation-related topics. RESULTS: Thirty-eight residents participated in the survey (response rate 95%). Resident understanding, comfort and belief regarding innovation-related topics improved significantly (P < .0001) on all nine Likert-scale questions after the course. After the course, a significant majority of residents either agreed or strongly agreed that technological innovation should be a core competency for the residency curriculum, and that a workshop to prototype their ideas would be beneficial. Performance on the course exam showed significant improvement (48% vs 86%, P < .0001). The overall course experience was rated 5 out of 5 by all participants. CONCLUSION: MESH Core demonstrates long-term success in educating future radiologists on the basic concepts of medical technological innovation. Years later, residents used the knowledge and experience gained from MESH Core to successfully pursue their own inventions and innovative projects. This innovation model may serve as an approach for other institutions to implement training in this domain.


Assuntos
Educação de Pós-Graduação em Medicina , Internato e Residência , Humanos , Educação de Pós-Graduação em Medicina/métodos , Competência Clínica , Currículo , Radiologistas , Hospitais
5.
Magn Reson Med ; 91(6): 2459-2482, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38282270

RESUMO

PURPOSE: To develop and evaluate methods for (1) reconstructing 3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse (3D-QALAS) time-series images using a low-rank subspace method, which enables accurate and rapid T1 and T2 mapping, and (2) improving the fidelity of subspace QALAS by combining scan-specific deep-learning-based reconstruction and subspace modeling. THEORY AND METHODS: A low-rank subspace method for 3D-QALAS (i.e., subspace QALAS) and zero-shot deep-learning subspace method (i.e., Zero-DeepSub) were proposed for rapid and high fidelity T1 and T2 mapping and time-resolved imaging using 3D-QALAS. Using an ISMRM/NIST system phantom, the accuracy and reproducibility of the T1 and T2 maps estimated using the proposed methods were evaluated by comparing them with reference techniques. The reconstruction performance of the proposed subspace QALAS using Zero-DeepSub was evaluated in vivo and compared with conventional QALAS at high reduction factors of up to nine-fold. RESULTS: Phantom experiments showed that subspace QALAS had good linearity with respect to the reference methods while reducing biases and improving precision compared to conventional QALAS, especially for T2 maps. Moreover, in vivo results demonstrated that subspace QALAS had better g-factor maps and could reduce voxel blurring, noise, and artifacts compared to conventional QALAS and showed robust performance at up to nine-fold acceleration with Zero-DeepSub, which enabled whole-brain T1, T2, and PD mapping at 1 mm isotropic resolution within 2 min of scan time. CONCLUSION: The proposed subspace QALAS along with Zero-DeepSub enabled high fidelity and rapid whole-brain multiparametric quantification and time-resolved imaging.


Assuntos
Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética Multiparamétrica , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas
6.
Inflamm Bowel Dis ; 30(3): 357-369, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37524088

RESUMO

BACKGROUND: Perianal fistulas and abscesses occur commonly as complications of pediatric Crohn's disease (CD). A validated imaging assessment tool for quantification of perianal disease severity and activity is needed to evaluate treatment response. We aimed to identify magnetic resonance imaging (MRI)-based measures of perianal fistulizing disease activity and study design features appropriate for pediatric patients. METHODS: Seventy-nine statements relevant to MRI-based assessment of pediatric perianal fistulizing CD activity and clinical trial design were generated from literature review and expert opinion. Statement appropriateness was rated by a panel (N = 15) of gastroenterologists, radiologists, and surgeons using modified RAND/University of California Los Angeles appropriateness methodology. RESULTS: The modified Van Assche Index (mVAI) and the Magnetic Resonance Novel Index for Fistula Imaging in CD (MAGNIFI-CD) were considered appropriate instruments for use in pediatric perianal fistulizing disease clinical trials. Although there was concern regarding the use of intravascular contrast material in pediatric patients, its use in clinical trials was considered appropriate. A clinically evident fistula tract and radiologic disease defined as at least 1 fistula or abscess on pelvic MRI were considered appropriate trial inclusion criteria. A coprimary clinical and radiologic end point and inclusion of a patient-reported outcome were also considered appropriate. CONCLUSION: Outcomes of treatment of perianal fistulizing disease in children must include MRI. Existing multi-item measures, specifically the mVAI and MAGNIFI-CD, can be adapted and used for children. Further research to assess the operating properties of the indices when used in a pediatric patient population is ongoing.


Assuntos
Doença de Crohn , Fístula , Humanos , Criança , Doença de Crohn/complicações , Doença de Crohn/diagnóstico por imagem , Imageamento por Ressonância Magnética , Abscesso
7.
Pediatr Radiol ; 54(2): 239-249, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38112762

RESUMO

BACKGROUND: Improving access to magnetic resonance imaging (MRI) in childhood can be facilitated by making it faster and cheaper and reducing need for sedation or general anesthesia (GA) to mitigate motion. Some children achieve diagnostic quality MRI without GA through the use of non- practices fostering their cooperation and/or alleviating anxiety. Employed before and during MRI, these variably educate, distract, and/or desensitize patients to this environment. OBJECTIVE: To assess current utilization of non-sedate practices in pediatric MRI, including variations in practice and outcomes. MATERIALS AND METHODS: A survey-based study was conducted with 1372 surveys emailed to the Society for Pediatric Radiology members in February 2021, inviting one response per institution. RESULTS: Responses from 50 unique institutions in nine countries revealed 49/50 (98%) sites used ≥ 1 non-sedate practice, 48/50 (96%) sites in infants < 6 months, and 11/50 (22%) for children aged 6 months to 3 years. Non-sedate practices per site averaged 4.5 (range 0-10), feed and swaddle used at 47/49 (96%) sites, and child life specialists at 35/49 (71%). Average success rates were moderate (> 50-75%) across all sites and high (> 75-100%) for 20% of sites, varying with specific techniques. Commonest barriers to use were scheduling conflicts and limited knowledge. CONCLUSION: Non-sedate practice utilization in pediatric MRI was near-universal but widely variable across sites, ages, and locales, with room for broader adoption. Although on average non-sedate practice success rates were similar, the range in use and outcomes suggest a need for standardized implementation guidelines, including patient selection and outcome metrics, to optimize utilization and inform educational initiatives.


Assuntos
Anestesia Geral , Imageamento por Ressonância Magnética , Lactente , Criança , Humanos , Movimento (Física) , Imageamento por Ressonância Magnética/métodos , Inquéritos e Questionários , Exame Físico
8.
Radiol Clin North Am ; 61(6): 1069-1083, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37758357

RESUMO

There is renewed interest in novel pediatric dual-energy computed tomography (DECT) applications that can image awake patients faster and at low radiation doses. DECT enables the simultaneous acquisition of 2 data sets at different energy levels, allowing for better material characterization and unique image reconstructions that enhance image analysis and provide quantitative and qualitative information about tissue composition. Pediatric DECT reduces radiation doses further while accelerating image acquisition and improving motion robustness. Current applications include the improved evaluation of congenital and acquired cardiovascular anomalies, lung perfusion and ventilation, renal stone composition, tumor extension and treatment response, and gastrointestinal diseases.

10.
Cancers (Basel) ; 15(10)2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-37345037

RESUMO

Pretreatment LDH is a standard prognostic biomarker for advanced melanoma and is associated with response to ICI. We assessed the role of machine learning-based radiomics in predicting responses to ICI and in complementing LDH for prognostication of metastatic melanoma. From 2008-2022, 79 patients with 168 metastatic hepatic lesions were identified. All patients had arterial phase CT images 1-month prior to initiation of ICI. Response to ICI was assessed on follow-up CT at 3 months using RECIST criteria. A machine learning algorithm was developed using radiomics. Maximum relevance minimum redundancy (mRMR) was used to select features. ROC analysis and logistic regression analyses evaluated performance. Shapley additive explanations were used to identify the variables that are the most important in predicting a response. mRMR selection revealed 15 features that are associated with a response to ICI. The machine learning model combining both radiomics features and pretreatment LDH resulted in better performance for response prediction compared to models that included radiomics or LDH alone (AUC of 0.89 (95% CI: [0.76-0.99]) vs. 0.81 (95% CI: [0.65-0.94]) and 0.81 (95% CI: [0.72-0.91]), respectively). Using SHAP analysis, LDH and two GLSZM were the most predictive of the outcome. Pre-treatment CT radiomic features performed equally well to serum LDH in predicting treatment response.

11.
Radiographics ; 43(6): e220192, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37167088

RESUMO

Gastrointestinal (GI) bleeding is a potentially life-threatening condition accounting for more than 300 000 annual hospitalizations. Multidetector abdominopelvic CT angiography is commonly used in the evaluation of patients with GI bleeding. Given that many patients with severe overt GI bleeding are unlikely to tolerate bowel preparation, and inpatient colonoscopy is frequently limited by suboptimal preparation obscuring mucosal visibility, CT angiography is recommended as a first-line diagnostic test in patients with severe hematochezia to localize a source of bleeding. Assessment of these patients with conventional single-energy CT systems typically requires the performance of a noncontrast series followed by imaging during multiple postcontrast phases. Dual-energy CT (DECT) offers several potential advantages for performing these examinations. DECT may eliminate the need for a noncontrast acquisition by allowing the creation of virtual noncontrast (VNC) images from contrast-enhanced data, affording significant radiation dose reduction while maintaining diagnostic accuracy. VNC images can help radiologists to differentiate active bleeding, hyperattenuating enteric contents, hematomas, and enhancing masses. Additional postprocessing techniques such as low-kiloelectron voltage virtual monoenergetic images, iodine maps, and iodine overlay images can increase the conspicuity of contrast material extravasation and improve the visibility of subtle causes of GI bleeding, thereby increasing diagnostic confidence and assisting with problem solving. GI bleeding can also be diagnosed with routine single-phase DECT scans by constructing VNC images and iodine maps. Radiologists should also be aware of the potential pitfalls and limitations of DECT. ©RSNA, 2023 Quiz questions for this article are available through the Online Learning Center.


Assuntos
Hemorragia Gastrointestinal , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Humanos , Hemorragia Gastrointestinal/diagnóstico por imagem , Intestino Delgado , Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos
14.
Cancers (Basel) ; 15(7)2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-37046718

RESUMO

BACKGROUND: The aim was to investigate the role of pre-ablation tumor radiomics in predicting pathologic treatment response in patients with early-stage hepatocellular carcinoma (HCC) who underwent liver transplant. METHODS: Using data collected from 2005-2015, we included adult patients who (1) had a contrast-enhanced MRI within 3 months prior to ablation therapy and (2) underwent liver transplantation. Demographics were obtained for each patient. The treated hepatic tumor volume was manually segmented on the arterial phase T1 MRI images. A vector with 112 radiomic features (shape, first-order, and texture) was extracted from each tumor. Feature selection was employed through minimum redundancy and maximum relevance using a training set. A random forest model was developed based on top radiomic and demographic features. Model performance was evaluated by ROC analysis. SHAP plots were constructed in order to visualize feature importance in model predictions. RESULTS: Ninety-seven patients (117 tumors, 31 (32%) microwave ablation, 66 (68%) radiofrequency ablation) were included. The mean model for end-stage liver disease (MELD) score was 10.5 ± 3. The mean follow-up time was 336.2 ± 179 days. Complete response on pathology review was achieved in 62% of patients at the time of transplant. Incomplete pathologic response was associated with four features: two first-order and two GLRM features using univariate logistic regression analysis (p < 0.05). The random forest model included two radiomic features (diagnostics maximum and first-order maximum) and four clinical features (pre-procedure creatinine, pre-procedure albumin, age, and gender) achieving an AUC of 0.83, a sensitivity of 82%, a specificity of 67%, a PPV of 69%, and an NPV of 80%. CONCLUSIONS: Pre-ablation MRI radiomics could act as a valuable imaging biomarker for the prediction of tumor pathologic response in patients with HCC.

15.
Cancer Med ; 12(8): 9902-9911, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36775966

RESUMO

BACKGROUND: This study examines the impact that the COVID-19 pandemic has had on computed tomography (CT)-based oncologic imaging utilization. METHODS: We retrospectively analyzed cancer-related CT scans during four time periods: pre-COVID (1/5/20-3/14/20), COVID peak (3/15/20-5/2/20), post-COVID peak (5/3/20-12/19/20), and vaccination period (12/20/20-10/30/21). We analyzed CTs by imaging indication, setting, and hospital type. Using percentage decrease computation and Student's t-test, we calculated the change in mean number of weekly cancer-related CTs for all periods compared to the baseline pre-COVID period. This study was performed at a single academic medical center and three affiliated hospitals. RESULTS: During the COVID peak, mean CTs decreased (-43.0%, p < 0.001), with CTs for (1) cancer screening, (2) initial workup, (3) cancer follow-up, and (4) scheduled surveillance of previously treated cancer dropping by 81.8%, 56.3%, 31.7%, and 45.8%, respectively (p < 0.001). During the post-COVID peak period, cancer screenings and initial workup CTs did not return to prepandemic imaging volumes (-11.4%, p = 0.028; -20.9%, p = 0.024). The ED saw increases in weekly CTs compared to prepandemic levels (+31.9%, p = 0.008), driven by increases in cancer follow-up CTs (+56.3%, p < 0.001). In the vaccination period, cancer screening CTs did not recover to baseline (-13.5%, p = 0.002) and initial cancer workup CTs doubled (+100.0%, p < 0.001). The ED experienced increased cancer-related CTs (+75.9%, p < 0.001), driven by cancer follow-up CTs (+143.2%, p < 0.001) and initial workups (+46.9%, p = 0.007). CONCLUSIONS AND RELEVANCE: The pandemic continues to impact cancer care. We observed significant declines in cancer screening CTs through the end of 2021. Concurrently, we observed a 2× increase in initial cancer workup CTs and a 2.4× increase in cancer follow-up CTs in the ED during the vaccination period, suggesting a boom of new cancers and more cancer examinations associated with emergency level acute care.


Assuntos
COVID-19 , Neoplasias , Humanos , COVID-19/epidemiologia , COVID-19/prevenção & controle , Pandemias/prevenção & controle , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Neoplasias/diagnóstico por imagem , Neoplasias/epidemiologia , Vacinação , Serviço Hospitalar de Emergência
16.
Pediatr Radiol ; 53(7): 1270-1284, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36261512

RESUMO

Magnetic resonance imaging (MRI) has emerged as the preferred imaging modality for evaluating a wide range of pediatric medical conditions. Nevertheless, the long acquisition times associated with this technique can limit its widespread use in young children, resulting in motion-degraded or non-diagnostic studies. As a result, sedation or general anesthesia is often necessary to obtain diagnostic images, which has implications for the safety profile of MRI, the cost of the exam and the radiology department's clinical workflow. Over the last decade, several techniques have been developed to increase the speed of MRI, including parallel imaging, single-shot acquisition, controlled aliasing techniques, compressed sensing and artificial-intelligence-based reconstructions. These are advantageous because shorter examinations decrease the need for sedation and the severity of motion artifacts, increase scanner throughput, and improve system efficiency. In this review we discuss a framework for image acceleration in children that includes the synergistic use of state-of-the-art MRI hardware and optimized pulse sequences. The discussion is framed within the context of pediatric radiology and incorporates the authors' experience in deploying these techniques in routine clinical practice.


Assuntos
Anestesia Geral , Imageamento por Ressonância Magnética , Humanos , Criança , Pré-Escolar , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Artefatos , Espectroscopia de Ressonância Magnética
17.
Eur Radiol ; 33(2): 1318-1328, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36074261

RESUMO

OBJECTIVES: To assess the impact of dual-energy CT (DECT) utilization in practice by measuring the readers' confidence, the need for additional image requests, and diagnostic performance in renal lesion assessment, compared to single-energy CT (SECT) using contrast-enhanced MRI to establish the reference standard. MATERIALS AND METHODS: Sixty-nine patients (M/F = 47/22) who underwent a dual-phase renal SECT (n = 34) or DECT (n = 35) and had a contrast-enhanced MRI within 180 days were retrospectively collected. Three radiologists assessed images on different sessions (SECT, DECT, and MRI) for (1) likely diagnosis (enhancing/non-enhancing); (2) diagnostic confidence (5-point Likert scale); (3) need for additional imaging test (yes/no); and (4) need for follow-up imaging (yes/no). Diagnostic accuracy was compared using AUC; p value < 0.05 was considered significant. RESULTS: One hundred fifty-six lesions consisting of 18% enhancing (n = 28/156, mean size: 30.37 mm, range: 9.9-94 mm) and 82% non-enhancing (n = 128/156, mean size: 23.91 mm, range: 5.0-94.2 mm) were included. The confidence level was significantly lower for SECT than their MRI (4.50 vs. 4.80, p value < 0.05) but not significantly different for DECT and the corresponding MRI (4.78 vs. 4.78, p > 0.05). There were significantly more requests for additional imaging in the SECT session than the corresponding MRI (20% vs. 4%), which was not significantly different between DECT and their MRI counterpart session (5.7% vs. 4.9%). Inter-reader agreement was almost perfect for DECT and MRI (kappa: 0.8-1) and substantial in SECT sessions (kappa: 0.6-0.8) with comparable diagnostic accuracy between SECT, DECT, and MRI (p value > 0.05). CONCLUSION: Single-phase DECT allows confident and reproducible characterization of renal masses with fewer recommendation for additional and follow-up imaging tests than dual-phase SECT and a performance similar to MRI. KEY POINTS: • DECT utilization leads to similar additional image requests to MRI (5.7% vs. 4.9%, p value > 0.05), whereas single-energy CT utilization leads to significantly higher image requests (20% vs. 4%, p value < 0.05). • DECT and MRI utilization bring highly reproducible results with almost perfect inter-reader agreement (kappa: 0.8-1), better than the inter-reader agreement in SECT utilization (kappa: 0.6-0.8). • Readers' confidence was not significantly altered between DECT and their MRI readout session (p value > 0.05). In contrast, confidence in the diagnosis was significantly lower in the SECT session than their MRI readout (p value < 0.05).


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Doses de Radiação , Imageamento por Ressonância Magnética
18.
Pediatr Nephrol ; 38(10): 3253-3264, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36445479

RESUMO

Tuberous sclerosis complex (TSC) is an autosomal dominant disorder with an estimated incidence of one in 5000 to 10,000 live births worldwide. Two million people of all races and genders are estimated to have TSC secondary to mutations in one of two tumor suppressor genes, TSC1 or TSC2. The respective TSC1 and 2 gene products - hamartin and tuberin - form cytoplasmic heterodimers that inhibit mTOR-mediated cell growth and division. When mTOR inhibition is lost, people with TSC develop characteristic and usually benign tumors in various organ systems. Kidney tumors and cysts are common, particularly in the setting of TSC2 gene mutations. In most TSC patients, the number of kidney cysts is limited, their morphology is simple, their size is small, and their clinical significance is negligible. In some, cyst morphology progresses from simple to complex with the risk of malignant transformation. In others, aggressive accumulation and growth of kidney cysts can cause hypertension, impaired kidney function, and progression to kidney failure. This educational review summarizes current knowledge and remaining open questions regarding cystic kidney disease in TSC, emphasizing detection, classification, surveillance, and treatment options.


Assuntos
Cistos , Neoplasias Renais , Doenças Renais Policísticas , Esclerose Tuberosa , Humanos , Feminino , Masculino , Proteínas Supressoras de Tumor/genética , Esclerose Tuberosa/complicações , Esclerose Tuberosa/epidemiologia , Esclerose Tuberosa/genética , Neoplasias Renais/etiologia , Neoplasias Renais/genética , Serina-Treonina Quinases TOR , Cistos/complicações
20.
Pediatr Radiol ; 53(7): 1300-1313, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36471168

RESUMO

Magnetic resonance imaging has emerged as a preferred modality in pediatric imaging because of its high soft-tissue contrast and the lack of ionizing radiation. It is important to recognize that despite its many advantages, several challenges to performing neonatal MRI arise from the lack of patient compliance and the small size of the anatomy. This manuscript presents the approach to patient preparation used at the authors' institution, summarizes general principles of image optimization and hardware selection, and reviews common indications across various organ systems. This manuscript also incorporates input from our pediatric-trained MRI technologists, in an attempt to compile a practical guideline covering all major aspects of neonatal MRI, from its execution to its interpretation.


Assuntos
Imageamento por Ressonância Magnética , Cooperação do Paciente , Recém-Nascido , Criança , Humanos , Imageamento por Ressonância Magnética/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...